Submit Your Article CMED MEACR meeting
Home Print this page Email this page Users Online: 740
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2012  |  Volume : 1  |  Issue : 2  |  Page : 65-70

An evaluation of three dimensional conformal radiation therapy versus intensity modulated radiation therapy in radical chemoradiation of esophageal cancer: A dosimetric study


1 Department of Radiotherapy and Oncology, Institute of Medical Education and Research, Chandigarh, India
2 Department of Surgical Gastroenterology, Institute of Medical Education and Research, Chandigarh, India
3 Department of Gastroenterology, Institute of Medical Education and Research, Chandigarh, India

Correspondence Address:
Rakesh Kapoor
Department of Radiotherapy and Oncology, Regional Cancer Centre, Post Graduate Institute of Medical Education and Research, Chandigarh - 160 012
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2278-0513.99565

Rights and Permissions

Aims: To evaluate the feasibility whether intensity-modulated radiotherapy (IMRT) can be used to reduce doses to normal thoracic structures than three-dimensional conformal radiotherapy (3DCRT) in treating esophageal cancer and to compare normal tissue complication probability (NTCP) for lung between two treatment plans. Materials and Methods: A prospective study was carried out from 2009 to 2011, in which 15 inoperable patients of esophageal cancer who were suitable for radical chemoradiation were enrolled. All patients were treated with 3DCRT. In first phase, patients were treated with external beam radiation therapy (EBRT) dose of 36Gy in 20 fractions in 4 weeks, along with concurrent weekly chemotherapy with cisplatinum and 5-fluorouracil (5 FU). In second phase, boost dose of 18Gy in 10 fractions in 2 weeks was given. An IMRT plan was generated for each patient. Plan sum of both the 3D CRT and IMRT plans were compared. Doses to critical structures and NTCP for lung were compared between 3DCRT and IMRT plans. Results: The mean lung dose and volumes of lung receiving 20 Gy, 10 Gy, and 5 Gy (V20, V10, and V5) were significantly lower with 3DCRT plans as compared to IMRT plans. The mean dose to heart and spinal cord was higher in 3DCRT arm. There was no difference in dose distribution to the liver between the 3D CRT and IMRT techniques. The NTCP for lung was lower with 3D CRT than IMRT. Conclusion: IMRT technique needs further dosimetric study as well as further clinical trials before implication of this technique replacing 3D CRT technique with escalated dose for the treatment of esophageal cancer in our setup. IMRT using seven fields provided no improvement over 3DCRT.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2747    
    Printed163    
    Emailed5    
    PDF Downloaded217    
    Comments [Add]    
    Cited by others 1    

Recommend this journal